Especificações resumidas
-
Max. measurement error
2% - 10% (per measurement range)
-
Measuring range
1"...40"
-
Medium temperature range
-20...+85°C
(-4...+185°F)
CIP able to 130°C / 266°F -
Max. process pressure
100 bar (1.740 psi)
Campo de aplicação
The switch is designed for the safe monitoring and display of relative mass flow rates of liquid media in hygienic applications, for example the monitoring of cooling water circulation systems and filter monitoring in the beverage industry. It can be selected between one or two switch outputs as well as one switch output and one standardized analog output for flow rates or temperature values. A variety of hygienic process connections leads to a flexible use.
Flow switch for monitoring and displaying relative mass flow rates of liquid media in the range from 0.03 to 3 m/s (0.1 to 9.84 ft/s). Flowphant T DTT35 − with process connections for hygienic applications.
Application examples:
Monitoring cooling water circulation systems of pumps, turbines, compressors and heat exchangers
Leak monitoring in process lines
Monitoring pump functionality
Monitoring lubrication systems
Filter monitoring in the beverage industry
Benefícios
Practically no pressure loss
Configuration software FieldCare for quick configuration and reliable storage of device settings
Optional: second switch output or 4 to 20 mA analog output for temperature monitoring or for outputting the flow as a percentage
Function check and process information onsite thanks to digital display at device
Top housing section which can be rotated 310° and rotatable display make it possible to read the measured values in all orientations
3-A approval
Versão Fundamental
-
Produtos simples
- Fácil de escolher, instalar e operar
Excelência técnica
Simplicidade
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
-
Informações Técnicas (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN PT 04/04/202425/03/202415/09/202328/10/202130/07/2021Idioma:
Português
Versão:
04/04/2024
Tamanho do arquivo:
1.2 MB
Nome do arquivo:
TI00426FPT_2524.pdf
-
-
-
Informações Técnicas (TI)
Flowphant T DTT31, DTT35
Chave de fluxo para monitoramento seguro e confiável de vazão mássica de
temperatura de processoEN PT 30/11/202015/02/201809/04/201416/08/201110/06/2009Idioma:
Português
Versão:
30/11/2020
Tamanho do arquivo:
1.1 MB
Nome do arquivo:
TI00125RPT_0420-00.pdf
-
-
-
Instruções de Operação (BA)
Flowphant T DTT31, DTT35
Chave de fluxo
EN PT 30/11/202015/02/201802/04/201416/01/201404/07/2013Idioma:
Português
Versão:
30/11/2020
Tamanho do arquivo:
1.1 MB
Nome do arquivo:
BA00235RPT_1820-00.pdf
-
-
-
Instruções de Operação (BA)
Operating Instructions Flow switch Flowphant T DTT31, DTT35
Flow switch for safe measurement and monitoring of mass flow and
temperature in industrial processesEN PT 08/02/2006Idioma:
Inglês
Versão:
08/02/2006
Tamanho do arquivo:
1023.5 KB
Nome do arquivo:
Ba218ren.pdf
-
-
-
Instruções de Operação (BA)
ReadWin® Quick Setup
Operating Manual
ReadWin® Quick Setup Temperature
PC SoftwareEN PT 02/02/2005Idioma:
Inglês
Versão:
02/02/2005
Tamanho do arquivo:
883.5 KB
Nome do arquivo:
Ba213ra2.pdf
-
-
-
Documentação especial (SD)
Device viewer
Technical documentation in other languages
Idioma:
Inglês
Versão:
14/07/2021
Tamanho do arquivo:
478.5 KB
Nome do arquivo:
SD02429R09EN_0121.pdf
-
-
-
Documentação especial (SD)
UKCA marking
Flow, density, concentration, viscosity
EN PT 04/11/202201/10/2021Idioma:
Inglês
Versão:
04/11/2022
Tamanho do arquivo:
357.4 KB
Nome do arquivo:
SD02752DEN_0222-00.pdf
-
-
-
Documentação especial (SD)
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411,
TT412, TE411, TK40, TMR35, DTT35, TTR35Idioma:
Inglês
Versão:
15/09/2023
Tamanho do arquivo:
800.3 KB
Nome do arquivo:
SD03119TEN_0123-00.pdf
-
-
-
Folheto de Competência (CP)
Catálogo soluciones esenciales
Alta calidad a precios competitivos
Idioma:
Espanhol
Versão:
16/01/2017
Tamanho do arquivo:
8.9 MB
Nome do arquivo:
CP01266Z.pdf
-
-
-
Declaração do Fabricante
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_01097_03.24
Manufacturer specification: Food hygieneIdioma:
Inglês
Versão:
24/10/2024
Tamanho do arquivo:
112.3 KB
Nome do arquivo:
HE_01097_03.24_en.pdf
-