Especificações resumidas
-
Max. measurement error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) -
Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
-
Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional -
Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
-
Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Campo de aplicação
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
Full compliance according to NACE MR0175 and MR0103
Nominal diameter: DN 25 to 300 (1 to 12")
Medium temperature: –40 to 200 °C (–40 to 392 °F)
Device as compact or remote version
2-line backlit display with push buttons
HART, PROFIBUS PA, FOUNDATION Fieldbus
Benefícios
Safe design for process industries – international hazardous area approvals
No additional pressure loss – full-bore design
Process transparency – diagnostic capability
Easy installation and reduced installation costs – loop-powered transmitter
Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
Automatic recovery of data for servicing
Vídeos
Seleção Extended
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
-
Instruções de Instalação (EA)
Safety Instructions for Spare Parts Installation Instructions
Versão em inglês - 03/2018
Flowmeter
EN PT 01/03/201828/11/201325/04/2013Idioma:
Inglês
Versão:
01/03/2018
Tamanho do arquivo:
139.5 KB
Nome do arquivo:
EA01051DA2_0318.pdf
-
-
-
Estudo de Caso (CS)
Where innovation meets tradition in Spirits production
Versão em inglês - 01/2022
Modernising traditional processes in a world class Craft Distillery expansion
Idioma:
Inglês
Versão:
12/01/2022
Tamanho do arquivo:
1.5 MB
Nome do arquivo:
CS01727D36EN_01.22_Where innovation meets tradition in Spirits production.pdf
-
-
-
Informações Técnicas (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN PT 05/11/201004/02/200901/06/2006Idioma:
Inglês
Versão:
05/11/2010
Tamanho do arquivo:
1.4 MB
Nome do arquivo:
TI00073DEN_1310.pdf
-
-
-
Instruções de Operação (BA)
Proline Prosonic Flow 92F FOUNDATION Fieldbus Operating Instructions
Ultrasonic Flow Measuring System
EN PT 08/11/201001/02/2008Idioma:
Inglês
Versão:
08/11/2010
Tamanho do arquivo:
3.3 MB
Nome do arquivo:
BA00128DEN_1310.pdf
-
-
-
Instruções de Operação (BA)
Prosonic Flow 92F PROFIBUS PA Operating Instructions
Ultrasonic Flow Measuring System, 2-Wire loop powered inline
flowmeterEN PT 11/11/201001/06/2006Idioma:
Inglês
Versão:
11/11/2010
Tamanho do arquivo:
3.6 MB
Nome do arquivo:
BA00122DEN_1310.pdf
-
-
-
Instruções de Operação (BA)
Proline Prosonic Flow 92F Operating Instructions
Ultrasonic Flow Measuring System
EN PT 05/11/201001/06/2006Idioma:
Inglês
Versão:
05/11/2010
Tamanho do arquivo:
3.5 MB
Nome do arquivo:
BA00121DEN_1310.pdf
-
-
-
Instruções curtas (KA)
Proline Prosonic Flow 92F Brief Operating Instructions
Ultrasonic flow measuring system
Two-wire inline flowmeterEN PT 01/09/2009Idioma:
Português
Versão:
01/09/2009
Tamanho do arquivo:
549.2 KB
Nome do arquivo:
KA038DPT_0909.pdf
-
-
-
Instruções de Instalação (EA)
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN PT 15/10/202401/10/201828/06/2012Idioma:
Inglês
Versão:
15/10/2024
Tamanho do arquivo:
797.3 KB
Nome do arquivo:
EA00098DA2_1624-00.pdf
-
-
-
Instruções de Instalação (EA)
EA Installing sensor parts
Prosonic Flow 92F, Prowirl 72, 73, 200
EN PT 16/10/202301/09/201714/01/201628/11/2013Idioma:
Inglês
Versão:
16/10/2023
Tamanho do arquivo:
2 MB
Nome do arquivo:
EA01085DA2_0423-00.pdf
-
-
-
Instruções de Instalação (EA)
Repair kit cover remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65EN PT 01/10/201813/11/201418/04/2014Idioma:
Inglês
Versão:
01/10/2018
Tamanho do arquivo:
216.9 KB
Nome do arquivo:
EA01108DA2_0318.pdf
-
-
-
Instruções de Instalação (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN PT 01/03/201828/11/201325/04/2013Idioma:
Inglês
Versão:
01/03/2018
Tamanho do arquivo:
139.5 KB
Nome do arquivo:
EA01051DA2_0318.pdf
-
-
-
Instruções de Instalação (EA)
Replacing transmitter parts
Prowirl 72, 73, Prosonic Flow 92
EN PT 03/03/202001/04/201913/12/2010Idioma:
Inglês
Versão:
03/03/2020
Tamanho do arquivo:
451.5 KB
Nome do arquivo:
EA00043DA2_1520.pdf
-