Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
532 nm, 785 nm, 1000 nm
Metal: Liga C276, aço inoxidável 316L ou titânio grau 2
Janela: Safira de ultra pureza
ATEX, CSA, IECEx
The Raman Rxn-40 probe is a sealed immersion probe for in situ Raman spectroscopy of liquid-phase samples in a laboratory or process plant setting. The process connection for the Raman Rxn-40 can be swaged, compression-mounted, flange-mounted, or installed in an Endress+Hauser flow cell, and is NeSSI compatible. These versatile options allow for direct insertion in slip-streams, drain-values, reactors, circulation loops, blend headers, and inlet or outlet pipework.
Chemical: reaction monitoring, blending, catalysis, feed and final product monitoring
Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
Oil & Gas: fuel blending, fuel characterization
Pharmaceutical: API reaction monitoring, crystallization, polymorph, blending
Customizable to your process
Robust design with a range of process connections
In situ/no transfer lines or fast-loops required
Faster, simpler installation
Support for a range of chemical processes and corrosivity requirements
Ensures safety and meets regulatory requirements
Suitable for hazardous/classified environments
Produtos com tecnologia de ponta
Excelência técnica
Simplicidade
Produtos com tecnologia de ponta
Excelência técnica
Simplicidade
Produtos especializados
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
System design and specifications for the Raman Rxn-40 probe
EN | PT | ||
13/12/2024
|
|
|
Idioma: |
Inglês |
Versão: |
13/12/2024 |
Tamanho do arquivo: |
1.2 MB |
Nome do arquivo: |
TI01655CEN_0524.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-40 probe
EN | PT | ||
02/12/2024
|
|
|
Idioma: |
Inglês |
Versão: |
02/12/2024 |
Tamanho do arquivo: |
1.7 MB |
Nome do arquivo: |
BA02181CEN_0424.pdf |
Quick start guide for the Raman Rxn-40 probe
Idioma: |
Inglês |
Versão: |
02/12/2024 |
Tamanho do arquivo: |
1.4 MB |
Nome do arquivo: |
KA01555CEN_0424.pdf |
Certificações de áreas classificadas e instruções de instalação para a
sonda Raman Rxn-40
EN | PT | ||
17/07/2024
|
|
|
|
21/06/2024
|
|
|
|
08/08/2023
|
|
|
Idioma: |
Português |
Versão: |
17/07/2024 |
Tamanho do arquivo: |
1.3 MB |
Nome do arquivo: |
XA02749CPT_0424.pdf |
An overview brochure about our Raman Rxn5 analyzer (including
the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe),
a Raman spectroscopy analyzer system for gas phase measurements
powered by Kaiser Raman technology.
Idioma: |
Inglês |
Versão: |
28/10/2021 |
Tamanho do arquivo: |
499.9 KB |
Nome do arquivo: |
PU01444CEN_0121.pdf |
This case study examines how USN used Raman spectroscopy,
including a Raman Rxn2 analyzer and a Rxn-40probe, to monitor
CO2 capture solvent quality in the chemical industry (note: this
application would also work with a Raman Rxn4 analyzer / the
oil & gas industry).
Idioma: |
Inglês |
Versão: |
31/01/2022 |
Tamanho do arquivo: |
876.1 KB |
Nome do arquivo: |
CS01714CEN_0222.pdf |
An overview brochure about our Raman spectroscopy analyzer systems,
powered by Kaiser Raman technology, for the chemical industry
(includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe,
Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).
Idioma: |
Inglês |
Versão: |
18/10/2021 |
Tamanho do arquivo: |
10.6 MB |
Nome do arquivo: |
IN01223CEN_0121.pdf |
ラマン分光法プローブ製品ラインナップに関する概要パンフレット
です。この製品ラインナップには、Rxn-10プローブ、Rxn-20プロー
ブ、Rxn-30プローブ、Rxn-40プローブ、Rxn-41プローブ、Rxn-45プ
ローブ、Rxn-46プローブ、およびプローブオプティクアクセサリ
(bIOオプティック、シングルユース向けラマンオプティックシス
テム/SUB、浸漬オプティック、非接触オプティック)が含まれてい
ます。これらはすべて、Kaiserラマンテクノロジーによって動作し
ます。
Idioma: |
Japonês |
Versão: |
24/06/2024 |
Tamanho do arquivo: |
5.4 MB |
Nome do arquivo: |
IN01225CJA_0121_Raman_spectroscopic_probes.pdf |
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.
Idioma: |
Inglês |
Versão: |
26/10/2021 |
Tamanho do arquivo: |
4.9 MB |
Nome do arquivo: |
IN01225CEN_0121.pdf |
-
Idioma: |
French |
Versão: |
16/03/2023 |
Tamanho do arquivo: |
776 KB |
Nome do arquivo: |
IN01225CFR.pdf |