Liquisys COM253 is a standard transmitter for use with COS41 and COS61 oxygen sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
The Liquisys COM253 transmitter works with Oxymax COS41 and Oxymax COS61 dissolved oxygen sensors in environmental applications, such as:
O2 control in the aeration basin
O2 control and monitoring of drinking water
Surface water monitoring
Process water treatment and monitoring
O2 control in fish farming for optimum growth conditions
Liquisys COM253 features the following protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP
PROFIBUS PA
Benefícios
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Reliable oxygen control: Current input for flow rate monitoring with controller shut off or for feedforward control.
Easy to operate and service: Simple single-point calibration in air, air-saturated water or in the medium, direct access for manual contact control.
Reduced maintenance: Automatic cleaning function (with Chemoclean) triggered by alarm or limit switch.
Fit for every application: Numerous extensions, e.g. P(ID) controller, timer, etc., allow for flexible adaption to all processes.
A AVR Waste em Botlek, Rotterdam, processa até 1,7 milhão de toneladas de resíduos residuais por ano. Descubra como eles otimizam a medição de pH graças à Endress+Hauser
Uso de água do mar nas descargas de banheiro pode economizar muita água potável. Para garantir um fornecimento constante de água, os sensores usados devem funcionar de forma confiável para atender os objetivos de qualidade da água (WQO).
A análise de efluentes, usando o Liquistation CSF48 e o Liquiport CSP48 mobile, pode oferecer informações valiosas sobre a ocorrência de infecções de Covid 19 em uma área específica
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.
Para mais detalhes, revise nossa Política de cookies .