With cost efficiency, optimal use of space, reliable operation, easy commissioning and hygienic design the TMR35 fulfills all the requirements in the Food & Beverage as well as in the Life Science industries. A variety of hygienic process connections leads to a high flexibility.
The TMR35 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR35 with process connections for hygienic applications.
Benefícios
Small, compact design made entirely of stainless steel
Extremely short response times
Highly accurate even with short insertion lengths
4-wire, Pt100 or PC-programmable transmitter with 4 to 20 mA output
Configuration and visualization with ReadWin® 2000 PC operating software, which is free of charge
Breakdown information in event of sensor break or sensor short-circuit, adjustable as per NAMUR NE43
Hygienic compatible design with 3-A marking and EHEDG certification; Marine approval
Este white paper explica como os sensores de temperatura calibráveis podem ser usados em engenharia de processos higiênicos. Ele detalha teoria e prática, bem como exemplos de aplicação. Saiba mais!
Chr. Hansen simplificou a monitoração e a calibração da temperatura, tanto em tratamentos críticos quanto UHT da solução de nutrientes usando o sensor de temperatura iTHERM TM411
Para aplicações gerais (TMR31) ou sanitárias (TMR35), com sensor Pt100
classe A e conexão de 4 fios
Opcionalmente com transmissor de 4 a 20 mA integrado, programável por PC
Para aplicações gerais (TMR31) ou sanitárias (TMR35), com sensor Pt100 classe A e conexão de 4 fios Opcionalmente com transmissor de 4 a 20 mA integrado, programável por PC
Misura della temperatura e componenti di sistema per i settori
alimentare e
farmaceutico.
PU (publicação)
Versão em italiano - 01/2020
New version available in English
Misura della temperatura e componenti di sistema per i settori alimentare e farmaceutico. La nuova frontiera dell'igiene: un'offerta complete per applicazioni igieniche e asettiche
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.
Para mais detalhes, revise nossa Política de cookies .