The Flexdip CYA112 is a modular assembly for sensor immersion in open basins, channels, or tanks. It allows nearly any kind of sensor mounting – chain, fixed, or free-swinging – and features a quick fastener for rapid and safe installation of Memosens or fixed-cable sensors. The assembly provides you with outstanding flexibility and enables you to optimally configure your measurement at low costs.
Flexdip CYA112 is a modular assembly for all measurements in open basins, channels and tanks in:
Wastewater treatment plants
Water works
Utilities of all industries
It forms a perfect team with the Flexdip CYH112 holder for simple sensor isolation.
The Flexdip team is suitable for all parameters, such as:
pH/ORP
Conductivity
Oxygen
Turbidity
Sludge level
Disinfection
UV photometry
Nutrients
Benefícios
The modular system allows an optimum configuration for every measuring place
Fast installation and exchange of Memosens sensors with contactless plug-in head
Twist-free installation of fixed-cable sensors
Easy to install and to maintain
Robust design: Suitable for process pressures up to 6 bar (87 psi)
A AVR Waste em Botlek, Rotterdam, processa até 1,7 milhão de toneladas de resíduos residuais por ano. Descubra como eles otimizam a medição de pH graças à Endress+Hauser
Descubra como a Heineken atende a todas as regulamentações para proteger o meio ambiente brasileiro com o sensor digital de nitrato ou SAC Viomax CAS51D da Endress+Hauser.
Holiferm produz biossurfactantes sustentáveis usando um processo de fermentação patenteado de separação por gravidade. A empresa buscava uma maneira de automatizar a medição da etapa de separação de fase crítica.
0 to 5 mg/l total chlorine or 0 to 20 mg/l total chlorine
Process temperature
0 to 55 °C , non-freezing (32 to 130 °F)
Process pressure
1 bar relative (14,5 psi relativ) Max. 2 bar (max. 29 psi)
Measuring method
Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines) All components are reduced at the working electrode Almost pH independent
0 to 5 mg/l total chlorine or 0 to 20 mg/l total chlorine
Process temperature
0 to 55 °C , non-freezing (32 to 130 °F)
Process pressure
1 bar relative (14,5 psi relativ) Max. 2 bar (max. 29 psi)
Measuring method
Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines) All components are reduced at the working electrode Almost pH independent