CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.
The Memosens data cable CYK10 is applied in Memosens systems measuring the following parameters:
pH/ORP
Dissolved oxygen (amperometric)
Conductive conductivity
Disinfection
Benefícios
Maximum process safety through non-contact, inductive and digital signal transmission: No contact corrosion, absolutely watertight, no interference potential.
Increased availability of the measuring point: Digital data transmission provides an automatic error message if the signal is lost.
More flexibility in plant planning and installation: Cable length up to 100 m is possible.
A AVR Waste em Botlek, Rotterdam, processa até 1,7 milhão de toneladas de resíduos residuais por ano. Descubra como eles otimizam a medição de pH graças à Endress+Hauser
Descubra como a Heineken atende a todas as regulamentações para proteger o meio ambiente brasileiro com o sensor digital de nitrato ou SAC Viomax CAS51D da Endress+Hauser.
Holiferm produz biossurfactantes sustentáveis usando um processo de fermentação patenteado de separação por gravidade. A empresa buscava uma maneira de automatizar a medição da etapa de separação de fase crítica.
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Instruções de Segurança Ex (XA)
Versão em inglês - 11/2016
New version available in English
Safety instructions for electrical apparatus for explosion-hazardous areas
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Instruções de Segurança Ex (XA)
Versão em inglês - 02/2016
New version available in English
Safety instructions for electrical apparatus for explosion-hazardous areas
Cabo de medição CYK10 Complemento ao BA00118C Instruçõesde segurança para equipamento elétrico em área classificada ATEX II 1G Ex ia IIC T3/T4/T6 Ga IECEx Ex ia IIC T3/T4/T6 Ga
Continue sua seleção entre todas as opções possíveis
Sua privacidade é muito importante
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.